About this unit
This unit has two halves. The first looks at specialised cells, where the membranes, channels, motors and signals of Units 2 to 5 are put to work: nerve cells that fire action potentials (Chapter 6.1), muscle cells that contract (6.2), and the rods, cones and pancreatic cells that sense light and glucose (6.3). The second half is the toolkit used to study any cell: light and fluorescence microscopes (6.4), electron and confocal microscopes (6.5), cell fractionation to isolate organelles (6.6), flow cytometry to measure thousands of single cells (6.7), and immunostaining to find where a protein sits (6.8). Each method builds on the one before it.
Chapters
- Nerve cells: structure and function advanced
- Muscle cells: types and function advanced
- Cells of vision and pancreatic cells advanced
- Light and fluorescence microscopy
- Electron and confocal microscopy advanced
- Cell fractionation and isolation of organelles
- Flow cytometry advanced
- Immunostaining and protein localization
How to use this book
- Read the lead paragraph and the figure of each chapter first; they carry the one idea.
- Cover the solution of the worked example and do it yourself with a pencil, then compare step by step.
- Answer each "Check yourself" question in your head or on paper before you open it.
6.1 Nerve cells: structure and function
A nerve cell, or neuron, is a cell built to carry a message fast and far: from your toe to your spinal cord in a few hundredths of a second. It sends an electrical signal along a long, thin axon and then a chemical signal across a small gap, the synapse. Other universities meet neurons in physiology courses.
Specialised cells: one genome, many jobs
Every cell in your body carries the same DNA, yet a neuron, a muscle fibre and a pancreatic β cell work nothing alike. Specialisation (differentiation) comes from which genes are switched on: each cell type makes its own proteins and builds its shape around one job. Chapters 6.1 to 6.3 look at four such cells.
Parts of a neuron
- Dendrites: short branches that receive signals from other cells.
- Cell body (soma): holds the nucleus and most ribosomes; its clumps of rough ER are called Nissl bodies.
- Axon hillock and initial segment: where the axon leaves the soma. Voltage-gated Na⁺ channels are densest here, so the action potential starts here.
- Axon: one long process, up to about a metre in human leg nerves, that carries the signal away from the soma.
- Myelin sheath: layers of membrane wrapped round the axon by Schwann cells (peripheral nerves) or oligodendrocytes (brain and spinal cord). The bare gaps between wraps are the nodes of Ranvier.
- Axon terminals: end in synapses, where vesicles of neurotransmitter wait.
By shape, neurons are multipolar (many dendrites, one axon; motor neurons), bipolar (one dendrite, one axon; retina) or pseudounipolar (one process that splits in two; sensory neurons).
Resting potential and the action potential
At rest the inside of a neuron is negative, about −70 mV. The Na⁺/K⁺-ATPase pumps 3 Na⁺ out and 2 K⁺ in per ATP, so K⁺ is high inside and Na⁺ high outside. The resting membrane is leaky mainly to K⁺, so K⁺ flows out until the negative charge left behind holds it back. The voltage at which one ion is in balance is its equilibrium potential, given by the Nernst equation:
E = (RT / zF) · ln(C_out / C_in) At 37 °C and z = +1: E = 61.5 mV × log₁₀(C_out / C_in)
Here R is the gas constant (8.314 J mol⁻¹ K⁻¹), T the temperature in kelvin, z the ion's charge, F the Faraday constant (96,485 C mol⁻¹) and C the ion concentration outside and inside.
- A stimulus depolarises the membrane to threshold, about −55 mV.
- Voltage-gated Na⁺ channels open, Na⁺ rushes in, and the inside swings to about +30 mV.
- Within about a millisecond the Na⁺ channels inactivate and voltage-gated K⁺ channels open. K⁺ leaves and the membrane repolarises.
- The K⁺ channels close slowly, so the voltage briefly undershoots below rest (after-hyperpolarisation) before leak channels and the pump restore −70 mV.
While the Na⁺ channels are inactivated (the refractory period) they cannot reopen, so the spike moves only forward. The action potential is all-or-none: a stronger stimulus gives more spikes per second, not a taller spike. In an unmyelinated axon the spike creeps along at about 1 m/s. In a myelinated axon it jumps from node to node (saltatory conduction), up to about 100 m/s, and only the nodes exchange ions, which saves ATP.
The synapse
At a chemical synapse the spike opens voltage-gated Ca²⁺ channels in the terminal. Ca²⁺ entry makes vesicles fuse with the membrane, and transmitter (acetylcholine, glutamate, GABA) crosses a cleft of about 20 nm. It binds ligand-gated channels on the next cell, which either excite it (cations in) or inhibit it (Cl⁻ in). The transmitter is then removed: acetylcholinesterase splits acetylcholine, and other transmitters are pumped back. Electrical synapses use gap junctions (Unit 5, Cell junctions and cell adhesion) and pass current directly.
Worked example
Question (6 marks). A mammalian neuron has K⁺ = 140 mM inside and 5 mM outside, Na⁺ = 15 mM inside and 145 mM outside, at 37 °C. Find EK and ENa. Explain why the resting potential (−70 mV) lies close to EK and the spike peak moves towards ENa.
- EK = 61.5 × log₁₀(5/140) = 61.5 × log₁₀(0.0357) = 61.5 × (−1.447) = −89 mV.
- ENa = 61.5 × log₁₀(145/15) = 61.5 × log₁₀(9.67) = 61.5 × 0.985 = +61 mV.
- At rest the membrane is far more permeable to K⁺ than to Na⁺, so the voltage sits near EK. A small Na⁺ leak pulls it up from −89 to about −70 mV.
- When voltage-gated Na⁺ channels open, Na⁺ permeability briefly dominates and the voltage heads towards ENa. It peaks below +61 mV (about +30 mV) because Na⁺ channels inactivate and K⁺ channels open first.
Exam traps
- The pump moves 3 Na⁺ out and 2 K⁺ in, not the reverse, and not 1:1.
- Schwann cells myelinate peripheral axons; oligodendrocytes myelinate in the brain and spinal cord. Examiners swap them.
- A stronger stimulus does not make a bigger spike; it makes more spikes per second.
- Repolarisation is K⁺ leaving the cell, not Na⁺ being pumped out. The pump is far too slow to shape one spike.
Check yourself
Remember Name the cells that form myelin in the PNS and in the CNS. 2 marks
Schwann cells in the peripheral nervous system; oligodendrocytes in the central nervous system.
Understand Why does an action potential travel only away from the soma? 3 marks
Behind the spike the Na⁺ channels are inactivated (refractory) and cannot reopen, so only the membrane ahead can be pushed to threshold.
Understand Explain the role of Ca²⁺ at a chemical synapse. 3 marks
The spike opens voltage-gated Ca²⁺ channels in the terminal; Ca²⁺ entry triggers synaptic vesicles to fuse with the membrane and release transmitter by exocytosis.
Apply Outside K⁺ rises from 5 to 10 mM (inside 140 mM). Find the new EK and say what happens to the resting potential. 4 marks
EK = 61.5 × log₁₀(10/140) = 61.5 × (−1.146) = −70 mV. EK becomes less negative, so the cell depolarises, sits nearer threshold and becomes more excitable; this is why high blood K⁺ disturbs heart rhythm.
Analyze Myelin raises conduction speed and saves energy. Explain both from the same mechanism. 5 marks
Myelin insulates the internode, so current spreads quickly inside the axon to the next node instead of leaking out. The spike is regenerated only at nodes: it jumps (faster), and ions cross the membrane only at nodes, so the pump has far fewer ions to move back (less ATP).
Beyond the syllabus
Not for the exam. Optogenetics puts light-gated channels into chosen neurons so a researcher can switch them on with a flash of blue light. Brain-computer interfaces read spikes from electrode arrays to move a cursor or a robotic arm. Search next: "patch clamp" and "optogenetics channelrhodopsin".
6.2 Muscle cells: types and function
A muscle cell turns chemical energy (ATP) into pulling force. Myosin motors walk along actin filaments, and because thousands of them pull at once, the whole cell shortens. Your body has three kinds of muscle cell, skeletal, cardiac and smooth, built on the same actin–myosin engine but switched on in different ways.
Three types of muscle cell
| Feature | Skeletal | Cardiac | Smooth |
|---|---|---|---|
| Shape | Long cylindrical fibre, many nuclei at the edge | Short, branched, usually one central nucleus | Spindle-shaped, one central nucleus |
| Striations | Yes (sarcomeres) | Yes (sarcomeres) | No |
| Control | Voluntary, by motor neurons | Involuntary, own pacemaker | Involuntary, nerves and hormones |
| Cell links | Each fibre separate | Intercalated discs with gap junctions | Gap junctions in many tissues |
| Ca²⁺ switch | Troponin on thin filament | Troponin on thin filament | Calmodulin and myosin light-chain kinase |
| Where | Limbs, trunk, face | Heart wall | Gut, blood vessels, uterus, bladder |
A skeletal muscle fibre is a single huge cell formed when many myoblasts fuse during development; that is why it has many nuclei. Inside, it is packed with myofibrils, each a chain of repeating units called sarcomeres.
The sarcomere and the sliding filament model
A sarcomere runs from one Z line (Z disc) to the next. Thin filaments of actin are anchored at the Z lines and point inwards; thick filaments of myosin sit in the middle, held at the M line. Under the microscope this gives bands:
- A band: the length of the thick filaments (dark, anisotropic). It does not change during contraction.
- I band: the part with thin filaments only (light, isotropic). It shortens.
- H zone: the middle of the A band, with thick filaments only. It shortens and can vanish.
The sliding filament model (A. F. Huxley and R. Niedergerke; H. E. Huxley and J. Hanson, both 1954) says the filaments do not shorten; they slide past each other, pulling the Z lines closer.
Cross-bridge cycle and excitation–contraction coupling
- A motor neuron releases acetylcholine at the neuromuscular junction; the fibre fires an action potential.
- The spike runs down T-tubules (inward folds of the plasma membrane). A voltage sensor there (the dihydropyridine receptor) opens ryanodine receptors in the sarcoplasmic reticulum (SR), and Ca²⁺ floods the cytosol.
- Ca²⁺ binds troponin C; troponin shifts tropomyosin off the myosin-binding sites on actin.
- A myosin head carrying ADP + Pi binds actin. Releasing Pi triggers the power stroke, pulling the thin filament towards the M line; ADP leaves.
- A fresh ATP binds and the head lets go of actin. Hydrolysis of that ATP re-cocks the head for the next cycle.
- When nerve firing stops, the SR Ca²⁺ pump (SERCA) takes Ca²⁺ back, tropomyosin covers the sites and the muscle relaxes.
ATP is needed both to detach myosin and to pump Ca²⁺ back. After death ATP runs out, heads stay locked on actin, and the muscles go stiff: rigor mortis. In smooth muscle, Ca²⁺ binds calmodulin, which activates myosin light-chain kinase; the phosphorylated myosin then binds actin. Cardiac cells add a Ca²⁺ entry step from outside and pass the spike to neighbours through gap junctions, so the heart contracts as one unit.
Worked example
Question (5 marks). In a frog muscle, thick filaments are 1.6 µm long and each thin filament (from a Z line) is 1.0 µm long. A sarcomere shortens from 2.5 µm to 2.0 µm. Find the A band, I band and H zone before and after.
- A band = thick filament length = 1.6 µm both times.
- I band = sarcomere − A band. Before: 2.5 − 1.6 = 0.9 µm. After: 2.0 − 1.6 = 0.4 µm.
- H zone = sarcomere − 2 × thin filament length. Before: 2.5 − 2.0 = 0.5 µm. After: 2.0 − 2.0 = 0 µm; the thin filaments now meet at the centre.
- Check: the I band lost 0.5 µm and the H zone lost 0.5 µm, equal to the 0.5 µm shortening, as sliding predicts.
Exam traps
- The A band never changes length. Only the I band and H zone shorten.
- ATP binding makes myosin let go of actin; the power stroke follows Pi release. Rigor is the state with no ATP.
- Smooth muscle has actin and myosin but no troponin and no sarcomeres; Ca²⁺ works through calmodulin.
- Cardiac muscle is striated but involuntary; do not pair "striated" with "voluntary".
Check yourself
Remember Name the protein that Ca²⁺ binds in skeletal muscle and in smooth muscle. 2 marks
Troponin C in skeletal (and cardiac) muscle; calmodulin in smooth muscle.
Understand Why are skeletal muscle fibres multinucleate? 2 marks
Each fibre forms by the fusion of many myoblasts during development, and their nuclei are kept.
Understand Explain rigor mortis using the cross-bridge cycle. 3 marks
After death ATP runs out. Myosin heads that have done their power stroke cannot detach without ATP, so they stay bound to actin and the muscle stays stiff until proteins break down.
Apply With the filament lengths of the worked example, what is the I band at a sarcomere length of 3.0 µm? 2 marks
I band = 3.0 − 1.6 = 1.4 µm.
Analyze Why must heart cells be electrically coupled while skeletal fibres are not? 4 marks
The heart must pump as one unit, so the spike from the pacemaker spreads cell to cell through gap junctions in the intercalated discs. Skeletal muscle needs graded force, so each fibre is driven by its own motor neuron and the brain chooses how many motor units to fire.
Beyond the syllabus
Not for the exam. Duchenne muscular dystrophy comes from loss of dystrophin, a protein linking the actin cytoskeleton to the membrane, and gene therapies for it are now in clinical use. Cultured meat grows skeletal muscle cells on scaffolds in bioreactors, a growing biotech industry. Search next: "dystrophin gene therapy" and "cultivated meat bioreactor".
6.3 Cells of vision and pancreatic cells
Two more specialised cells show how the same signalling parts from Unit 5 are rewired for very different jobs. A rod or cone in the retina turns a photon into a change in membrane voltage. A pancreatic cell either secretes digestive enzymes into the gut or senses blood glucose and releases a hormone.
Rods and cones
Photoreceptors are neurons with a light-catching outer segment, a stack of membrane discs full of visual pigment, joined by a thin cilium to an inner segment rich in mitochondria, then a nucleus and a synaptic terminal. Rods (about 120 million per human eye) are very sensitive and work in dim light, but give no colour. Cones (about 6 million, packed in the fovea) need brighter light and give sharp, colour vision. Humans have three cone types, most sensitive to short (blue, about 420 nm), medium (green, about 530 nm) and long (red-yellow, about 560 nm) wavelengths.
Phototransduction: light closes channels
The rod pigment rhodopsin is a GPCR: the protein opsin with 11-cis-retinal (from vitamin A) bound inside. In the dark, cGMP holds cation channels open, so Na⁺ and Ca²⁺ flow in (the "dark current"), the rod sits at about −40 mV and releases glutamate steadily.
- A photon isomerises 11-cis-retinal to all-trans-retinal; rhodopsin changes shape (activated rhodopsin).
- Activated rhodopsin activates many molecules of the G protein transducin.
- Transducin's α subunit switches on phosphodiesterase (PDE6), which hydrolyses cGMP.
- cGMP falls, the cGMP-gated channels close, and the rod hyperpolarises towards about −70 mV.
- Glutamate release drops; the next neurons (bipolar cells) read this drop as "light".
Each step multiplies the signal, which is why a rod can respond to a single photon. Notice the twist: light makes a photoreceptor hyperpolarise, the opposite of most sensory cells.
Pancreatic cells: exocrine and endocrine
Nearly all of the pancreas is exocrine (the islets are only about 1–2% of its mass): acinar cells that make digestive enzymes (trypsinogen, amylase, lipase) on rough ER, pack them in the Golgi into zymogen granules at the cell apex, and release them by exocytosis into ducts. George Palade worked out the secretory pathway by following labelled protein through these very cells. Enzymes leave as inactive precursors so they do not digest the pancreas itself.
Scattered among them are the islets of Langerhans, the endocrine part: β cells make insulin, α cells glucagon, δ cells somatostatin and PP cells pancreatic polypeptide. β cells are the most numerous islet cell.
A β cell is a glucose sensor wired to a secretory machine:
- Glucose enters through glucose transporters and is phosphorylated by glucokinase, which works in proportion to blood glucose.
- Glycolysis and mitochondria raise the ATP/ADP ratio.
- ATP closes ATP-sensitive K⁺ channels (KATP); less K⁺ leaves, so the cell depolarises.
- Voltage-gated Ca²⁺ channels open; Ca²⁺ triggers exocytosis of insulin granules.
Worked example
Question (6 marks). (a) Sulfonylurea drugs, used in type 2 diabetes, bind and close the KATP channel. Predict their effect on insulin release. (b) Some babies are born with a KATP channel that stays open even when ATP is high. Predict the effect, and suggest a treatment.
- (a) Closing KATP mimics high ATP: K⁺ outflow drops, the β cell depolarises, Ca²⁺ channels open and insulin is released, even at modest glucose. So sulfonylureas raise insulin secretion; their risk is low blood sugar.
- (b) If the channel cannot close, glucose metabolism raises ATP but the cell stays hyperpolarised. Ca²⁺ channels stay shut and little insulin is released: the baby has diabetes from birth (neonatal diabetes).
- Treatment logic: a drug that closes the channel by another route can restore depolarisation. Many such patients are indeed treated with high-dose sulfonylureas instead of insulin injections.
Exam traps
- Light hyperpolarises rods and cones; it does not depolarise them. Glutamate release falls in light.
- cGMP, not cAMP, is the second messenger in photoreceptors; PDE breaks it down.
- β cells make insulin and α cells make glucagon; the letters are swapped often.
- Rods: dim light, no colour, one pigment. Cones: bright light, colour, three pigments.
Check yourself
Remember Name the four cell types of an islet and the hormone each makes. 2 marks
β: insulin; α: glucagon; δ: somatostatin; PP: pancreatic polypeptide.
Remember What are the two parts of rhodopsin? 1 mark
The protein opsin and the chromophore 11-cis-retinal.
Understand Why does vitamin A deficiency cause night blindness? 3 marks
Retinal is made from vitamin A. Without it rods cannot rebuild rhodopsin, and rods are the cells that work in dim light, so vision fails first at night.
Apply A drug blocks PDE6 in rods. What happens to the dark current when light falls on the rod? 3 marks
cGMP cannot be broken down, so the cGMP-gated channels stay open; the dark current continues, the rod does not hyperpolarise and the light is not signalled.
Analyze Compare how an acinar cell and a β cell decide when to secrete. 5 marks
Both store product in granules made through ER and Golgi and release by Ca²⁺-triggered exocytosis. The acinar cell responds to hormones and nerves from the gut after a meal; the β cell reads blood glucose itself through its metabolism and the KATP channel. Acinar products go into ducts; insulin goes into blood.
Beyond the syllabus
Not for the exam. Researchers now make insulin-secreting β-like cells from stem cells (see Unit 4, Stem cells) and transplant them, and some type 1 diabetes trials have reported patients producing their own insulin again. Gene therapy for an inherited retinal disease (RPE65 mutation) is an approved product. Search next: "stem cell derived beta cells" and "retinal gene therapy RPE65".
6.4 Light and fluorescence microscopy
Most cells are 10 to 100 µm across, too small for the eye (which resolves about 0.1 mm), so cell biology began with the light microscope. A light microscope uses glass lenses to magnify an image formed by visible light; a fluorescence microscope lights the sample with one colour and collects the different colour that tagged molecules glow with, so you see only what you labelled.
Magnification is not resolution
In a compound microscope the objective lens near the sample forms a magnified image, and the eyepiece (ocular) magnifies it again. Total magnification = objective × eyepiece, so a 40× objective with a 10× eyepiece gives 400×. Below the stage, the condenser focuses light from the lamp onto the sample, and its diaphragm controls the cone of light.
Magnification only makes the picture bigger. Resolution is the smallest distance d at which two points still look like two. Because light is a wave, a point spreads into a small blur, and two blurs closer than about d merge. The Rayleigh criterion gives:
d = 0.61 λ / NA NA = n · sin θ
Here λ is the wavelength of light, NA the numerical aperture of the objective (engraved on its barrel), n the refractive index of the medium between lens and sample, and θ half the angle of the cone of light the objective accepts. A smaller d is better. Two ways to improve it: use shorter λ (blue rather than red) or larger NA. Air has n = 1.0, so a dry objective's NA stays below 1. Immersion oil has n ≈ 1.515, close to glass, so oil objectives reach NA ≈ 1.4. This sets the classic limit of about 0.2 µm: mitochondria and bacteria can be seen; ribosomes (about 25 nm) and membranes cannot. Magnifying beyond about 1000 × NA adds size but no new detail ("empty magnification").
Getting contrast
Living cells are mostly water and nearly transparent, so in plain bright-field they show little detail. Four answers:
- Staining fixed cells with dyes: methylene blue or haematoxylin colour nuclei; eosin colours cytoplasm pink; Gram stain separates bacteria. Staining usually kills the cell.
- Phase contrast (Zernike, 1930s): converts the tiny delay that light suffers passing through denser parts (nucleus, organelles) into differences in brightness. Ideal for live, unstained cells in culture.
- Differential interference contrast (DIC, Nomarski): uses polarised light to show gradients of optical thickness, giving a shaded, 3D-looking image.
- Dark-field: blocks direct light, so only light scattered by the sample enters the objective; objects shine bright on black.
Sample preparation, as in a teaching lab: a wet mount is a drop of live sample under a coverslip, for motility and shape; a dry, fixed smear is spread thin, air-dried, heat- or chemically fixed, then stained. Thick tissues are fixed, embedded in paraffin wax and cut into sections a few micrometres thick with a microtome before staining.
Fluorescence microscopy
A fluorophore absorbs a photon of one wavelength (excitation) and, a few nanoseconds later, emits a photon of longer wavelength (emission), because some energy is lost as heat in between. This shift to longer wavelength is the Stokes shift, and it is the whole trick: if you block the excitation colour and pass only the emission colour, only labelled structures appear, glowing on a black background.
Most instruments are epifluorescence microscopes: light comes down through the objective and the glow goes back up through the same objective. The filter cube has three parts:
- Excitation filter: passes only the band that excites the dye (blue for green-emitting dyes).
- Dichroic mirror at 45°: reflects the short excitation wavelengths down to the sample but lets the longer emission wavelengths pass up.
- Emission (barrier) filter: removes any leftover excitation light, passing only the emission band to the eye or camera.
Common labels: DAPI and Hoechst bind DNA and glow blue (excited by UV light near 360 nm); FITC and Alexa Fluor 488 glow green (excited near 490 nm); rhodamine-type dyes glow red. Green fluorescent protein (GFP), from the jellyfish Aequorea victoria, can be fused to any protein by genetic engineering, so a living cell shows where that protein is (Chapter 6.8). Shimomura, Chalfie and Tsien shared the 2008 Nobel Prize in Chemistry for it. Two practical limits: photobleaching (the fluorophore is destroyed by strong light, so the signal fades) and out-of-focus glow from thick samples, which the confocal microscope removes (Chapter 6.5).
Worked example 1: resolution
Question (4 marks). Find the resolution with green light (λ = 550 nm) for (a) a dry 40× objective, NA 0.65, and (b) an oil 100× objective, NA 1.40. Can either separate two vesicles 300 nm apart?
- (a) d = 0.61 × 550 / 0.65 = 335.5 / 0.65 = 516 nm ≈ 0.52 µm.
- (b) d = 0.61 × 550 / 1.40 = 335.5 / 1.40 = 240 nm ≈ 0.24 µm.
- 300 nm is larger than 240 nm but smaller than 516 nm, so only the oil objective shows two vesicles; the dry lens shows one blur.
Worked example 2: counting cells with a haemocytometer
Question (4 marks). A yeast culture is diluted 1:10 and loaded on an improved Neubauer haemocytometer. Counts in the four large corner squares (each 1 mm × 1 mm, chamber depth 0.1 mm) are 52, 48, 55 and 45. Find the cells per mL in the original culture.
- Mean count per large square = (52 + 48 + 55 + 45) / 4 = 200 / 4 = 50 cells.
- Volume over one large square = 1 mm × 1 mm × 0.1 mm = 0.1 mm³ = 0.1 µL = 1 × 10⁻⁴ mL.
- Cells per mL in the diluted sample = 50 / 10⁻⁴ = 5.0 × 10⁵.
- Undo the dilution: 5.0 × 10⁵ × 10 = 5.0 × 10⁶ cells/mL.
Exam traps
- Higher magnification does not mean better resolution; resolution depends on λ and NA only.
- Smaller d means better resolving power. Students often say "resolution increased" when d grew.
- Emission is at a longer wavelength than excitation, never shorter.
- The dichroic mirror reflects excitation and transmits emission; it is not an ordinary mirror or a filter that blocks both.
- In the haemocytometer, one large square holds 10⁻⁴ mL; forgetting the depth (0.1 mm) gives an answer 10 times too small.
Check yourself
Remember Write the Rayleigh equation and define NA. 2 marks
d = 0.61 λ / NA, with NA = n sin θ (n: refractive index of the medium; θ: half-angle of the light cone the objective accepts).
Remember Name the three parts of a fluorescence filter cube. 3 marks
Excitation filter, dichroic mirror, emission (barrier) filter.
Understand Why does immersion oil improve resolution? 3 marks
Oil (n ≈ 1.515) matches glass, so light bent at wide angles is not lost by refraction at an air gap; the objective collects a wider cone, NA rises to about 1.4 and d falls.
Understand Which method would you use to watch unstained live cells divide, and why? 2 marks
Phase contrast (or DIC): it turns differences in optical path into brightness, so transparent living cells show detail without stains that would kill them.
Apply Find d for blue light (450 nm) with NA 1.40. 2 marks
d = 0.61 × 450 / 1.40 = 196 nm ≈ 0.20 µm; shorter λ gives finer resolution.
Apply Haemocytometer counts of 30, 34, 28 and 28 cells in the four large squares, undiluted sample. Cells per mL? 3 marks
Mean = 120 / 4 = 30; 30 / 10⁻⁴ = 3.0 × 10⁵ cells/mL.
Analyze A student sees a dim green signal everywhere in a thick tissue slice and it fades over a minute. Explain both observations and suggest fixes. 5 marks
Everywhere-glow: fluorescence from planes above and below focus is also collected in a widefield microscope; use thinner sections or a confocal microscope. Fading: photobleaching; reduce light intensity or exposure, use an antifade mounting medium or a more stable dye.
Beyond the syllabus
Not for the exam. Super-resolution methods such as STED, PALM and STORM beat the 0.2 µm limit by switching fluorophores on and off so that nearby molecules glow at different times; they won the 2014 Nobel Prize in Chemistry. Light-sheet microscopy lights only a thin plane, so whole embryos can be filmed for days with little bleaching. Expansion microscopy swells the sample itself in a gel. Search next: "STED microscopy", "light-sheet microscopy" and "expansion microscopy".
6.5 Electron and confocal microscopy
When light cannot resolve a structure, use electrons; when a fluorescent sample is too thick and blurred, use a pinhole. Electron microscopes (TEM and SEM) replace light with an electron beam whose wavelength is about 100,000 times shorter, and show membranes, ribosomes and viruses. The confocal microscope keeps fluorescence but rejects out-of-focus light, giving sharp optical slices and 3D images of cells.
Transmission electron microscope (TEM)
A heated filament or field-emission gun produces electrons, which are accelerated by a high voltage (typically 80 to 300 kV) down a column kept under vacuum (air would scatter them). Electromagnetic coils act as lenses. Electrons pass through a very thin sample; dense regions scatter electrons away and look dark, giving a 2D projection on a fluorescent screen or camera. For biological sections the practical resolution is a few nanometres, set by the sample, not the beam.
Sample preparation for thin-section TEM:
- Fixation with glutaraldehyde (cross-links proteins), then osmium tetroxide (fixes and stains lipids).
- Dehydration through rising concentrations of ethanol or acetone, since water boils in vacuum.
- Embedding in epoxy resin, which hardens into a block.
- Ultrathin sectioning (about 50–100 nm) on an ultramicrotome with a diamond or glass knife.
- Heavy-metal staining with uranyl acetate and lead citrate, which bind membranes and nucleic acids and scatter electrons.
Other routes: negative staining surrounds viruses or protein complexes with heavy-metal salt so they appear light on dark; cryo-EM freezes samples so fast that water forms glass-like (vitreous) ice and averages thousands of images to solve protein structures (2017 Nobel Prize in Chemistry).
Scanning electron microscope (SEM)
An SEM scans a focused beam across the surface of the sample. Secondary electrons knocked out of the surface are collected and turned into an image with a striking 3D look, ideal for cell shape, microvilli, cilia and bacteria on a surface. Samples are fixed, dehydrated, dried by critical-point drying (to avoid collapse from surface tension) and coated with a thin layer of gold or another metal by sputter coating so they conduct. Resolution is usually lower than TEM, a few nanometres or more.
Confocal microscope
In a widefield fluorescence microscope the whole depth of the sample glows, so a thick specimen gives a blur. A confocal microscope (the idea patented by Marvin Minsky) focuses a laser to a point in the sample and places a pinhole in front of the detector at the plane conjugate to that focal point. Light from the focal point passes the pinhole; light from planes above and below is out of focus at the pinhole and is blocked. Scanning the point across the field builds one sharp optical section; moving the focus in steps gives a z-stack that software turns into a 3D image. The price: slower imaging and more photobleaching than widefield.
Worked example
Question (5 marks). The de Broglie wavelength of an electron accelerated through V volts is about λ = 1.226 / √V nm (ignoring relativity). Find λ at 100 kV, compare it with green light (550 nm), and explain why biological TEM images do not reach this limit.
- √V = √100,000 = 316.2.
- λ = 1.226 / 316.2 = 0.0039 nm (the relativistic value is a little shorter, about 0.0037 nm).
- Ratio: 550 / 0.0039 ≈ 1.4 × 10⁵, so the electron wavelength is over 100,000 times shorter.
- In practice, electron lenses have a small aperture and large aberrations, and biological samples are damaged by the beam, have low contrast and are limited by fixation, sectioning and stain grain. So stained sections resolve a few nanometres, still about 100 times better than the light microscope (about 200 nm).
Exam traps
- TEM: electrons pass through a thin section, 2D internal detail. SEM: surface scanning, 3D-looking surface. Do not swap them.
- Living cells cannot be seen in a conventional EM: vacuum, fixation and dehydration are required.
- The confocal pinhole sits in front of the detector, not in front of the lamp alone; it is the detector pinhole that rejects out-of-focus light.
- Electron lenses are electromagnetic coils, not glass.
Check yourself
Remember Name the two heavy-metal stains used for TEM sections. 2 marks
Uranyl acetate and lead citrate (osmium tetroxide also fixes and stains lipids).
Understand Why must an electron microscope column be under vacuum? 2 marks
Gas molecules would scatter the electrons and blur or stop the beam (and the filament would oxidise).
Understand Why are SEM samples coated with gold? 2 marks
The metal makes the surface conductive, so charge from the beam drains away, and it gives a strong secondary-electron signal.
Apply Choose a method: (a) shape of pollen grain surfaces; (b) cristae inside mitochondria; (c) 3D shape of a GFP-tagged Golgi in a living cell. 3 marks
(a) SEM; (b) TEM of thin sections; (c) confocal microscopy with a z-stack.
Analyze What happens to a confocal image if the pinhole is opened very wide, and why? 3 marks
More light reaches the detector (brighter), but out-of-focus light also passes, so the optical section gets thicker and the image blurs towards a widefield picture.
Beyond the syllabus
Not for the exam. Cryo-electron tomography images frozen cells from many angles to see molecular machines in their native place. Volume EM (serial block-face SEM) maps the wiring of whole brain regions. Two-photon microscopes excite with infrared pulses to image deep inside living tissue. Search next: "cryo-electron tomography" and "two-photon microscopy".
6.6 Cell fractionation and isolation of organelles
Cell fractionation breaks cells open gently and separates their parts, so that nuclei, mitochondria or ER membranes can be studied in a test tube. It is how biologists proved what each organelle does: Albert Claude, Christian de Duve and George Palade shared the 1974 Nobel Prize in Physiology or Medicine for this work, which found lysosomes and peroxisomes. The method has two steps, breaking the cells (homogenisation) and sorting the pieces by centrifugation.
Step 1: homogenisation
The aim is to break the plasma membrane (and the cell wall in plants or fungi) but keep organelles whole. Common methods:
- Potter–Elvehjem or Dounce homogeniser: a pestle turning or moving in a close-fitting glass tube; shear forces tear soft tissue such as liver.
- Blender for tough tissue; sonication (ultrasound) and the French press (forcing cells through a narrow valve under high pressure) for bacteria and yeast.
- Osmotic lysis: cells without a wall swell and burst in a hypotonic solution.
- Enzymes: cellulase and pectinase for plant walls, lysozyme for bacteria.
The homogenisation buffer matters as much as the force. It is isotonic (commonly 0.25 M sucrose; mannitol is also used), so organelles neither swell nor shrink; buffered near pH 7.4; ice-cold (0–4 °C) to slow enzymes; and often contains protease inhibitors and EDTA (which binds metal ions that activate degrading enzymes).
Step 2: differential centrifugation
In a centrifuge, a particle feels a force many times gravity. This relative centrifugal force (RCF), quoted as "× g", depends on the radius r and the speed:
RCF = 1.118 × 10⁻⁵ × r × (rpm)² (r in cm)
Larger and denser particles sediment faster. A particle's sedimentation rate per unit field is its sedimentation coefficient, s = v / (ω² r), where v is its velocity, ω the angular speed in rad/s and r the distance from the axis; s is measured in svedbergs (1 S = 10⁻¹³ s). That is why ribosomes are called 70S and 80S.
Differential centrifugation spins the homogenate at a series of rising speeds. After each spin the pellet is kept and the supernatant moves to the next, faster spin. Typical values (protocols differ):
- About 1,000 × g for 10 min: nuclei, unbroken cells and large debris pellet.
- About 10,000–20,000 × g for 20 min: mitochondria, lysosomes and peroxisomes (and chloroplasts from plant tissue).
- About 80,000–100,000 × g for 1 h (ultracentrifuge): microsomes, small vesicles formed from ER and plasma membrane during homogenisation.
- About 150,000 × g for several hours: ribosomes and large macromolecular complexes. The final supernatant is the cytosol.
Density-gradient centrifugation: cleaning up a fraction
Differential pellets are enriched, not pure: mitochondria, lysosomes and peroxisomes overlap in size. A density gradient separates them further.
- Rate-zonal (velocity) centrifugation: the sample is layered on a shallow gradient (for example 5–20% sucrose) and spun for a set time. Particles move as bands by size and shape (their s value); the run is stopped before they reach the bottom. Used for ribosomal subunits and polysomes.
- Isopycnic (equilibrium) centrifugation: a steep gradient (sucrose, Percoll or Nycodenz for organelles; caesium chloride for DNA) is spun until each particle stops at the layer whose density equals its own. Separation is by density only, not size. Peroxisomes are denser than mitochondria and band lower.
Checking the fractions: marker enzymes
Each organelle has an enzyme or molecule found almost nowhere else. Measuring it in every fraction tells you where that organelle went and how pure each fraction is.
| Organelle | Marker |
|---|---|
| Nucleus | DNA |
| Mitochondria | Succinate dehydrogenase, cytochrome c oxidase |
| Lysosomes | Acid phosphatase |
| Peroxisomes | Catalase |
| Endoplasmic reticulum (microsomes) | Glucose-6-phosphatase |
| Golgi | Galactosyltransferase |
| Plasma membrane | Na⁺/K⁺-ATPase, 5′-nucleotidase |
| Cytosol | Lactate dehydrogenase |
Purity is reported as specific activity (enzyme units per mg protein). Enrichment (fold purification) = specific activity in the fraction ÷ specific activity in the homogenate, and yield = total units in the fraction ÷ total units in the homogenate × 100%. Today, Western blots for organelle marker proteins (Chapter 6.8) are also used.
Worked example 1: setting the centrifuge
Question (4 marks). A rotor has a radius of 8.0 cm. What speed in rpm gives (a) 10,000 × g and (b) 100,000 × g?
- Rearrange: rpm = √[RCF / (1.118 × 10⁻⁵ × r)].
- 1.118 × 10⁻⁵ × 8.0 = 8.944 × 10⁻⁵.
- (a) rpm = √(10,000 / 8.944 × 10⁻⁵) = √(1.118 × 10⁸) ≈ 10,600 rpm.
- (b) rpm = √(100,000 / 8.944 × 10⁻⁵) = √(1.118 × 10⁹) ≈ 33,400 rpm. Ten times the force needs only √10 ≈ 3.2 times the speed.
Worked example 2: enrichment and yield
Question (5 marks). A liver homogenate has 500 mg protein and 25 units of succinate dehydrogenase (SDH). The 20,000 × g pellet has 20 mg protein and 12 units of SDH. Find the specific activities, the enrichment and the yield of mitochondria. The pellet also shows high catalase activity: what does that mean?
- Homogenate specific activity = 25 / 500 = 0.05 U/mg.
- Pellet specific activity = 12 / 20 = 0.60 U/mg.
- Enrichment = 0.60 / 0.05 = 12-fold.
- Yield = 12 / 25 × 100 = 48%; the rest of the mitochondria were lost in other fractions or broken.
- Catalase marks peroxisomes, which co-sediment with mitochondria. The pellet is contaminated; an isopycnic gradient would separate them.
Exam traps
- Quote centrifuge settings in × g, not rpm: the same rpm gives different forces in rotors of different radius.
- Microsomes are not an organelle in the living cell; they are vesicles made by breaking the ER and other membranes.
- Rate-zonal separates by size (stopped before equilibrium); isopycnic separates by density (run to equilibrium). This is the classic 8-mark comparison.
- In differential centrifugation the pellet is kept and the supernatant spun again; students reverse this.
- High enrichment with low yield is common and is not an error.
Check yourself
Remember Give the marker enzyme for lysosomes, peroxisomes and ER. 3 marks
Acid phosphatase; catalase; glucose-6-phosphatase.
Remember What is one svedberg? 1 mark
10⁻¹³ seconds, the unit of sedimentation coefficient.
Understand Why is the homogenisation buffer isotonic and ice-cold? 3 marks
Isotonic sucrose stops organelles swelling and bursting by osmosis; the cold slows proteases, lipases and nucleases released from broken lysosomes and cytosol.
Understand Why do mitochondria and peroxisomes end up in the same differential pellet, and how are they separated? 3 marks
They are similar in size, so they sediment at similar speeds. They differ in density, so isopycnic gradient centrifugation bands them at different heights.
Apply A rotor of radius 10 cm runs at 15,000 rpm. What is the RCF? 2 marks
RCF = 1.118 × 10⁻⁵ × 10 × (15,000)² = 1.118 × 10⁻⁴ × 2.25 × 10⁸ ≈ 25,200 × g.
Apply A homogenate has catalase specific activity 0.2 U/mg; a gradient fraction has 3.0 U/mg. What is the enrichment? 2 marks
3.0 / 0.2 = 15-fold.
Analyze After homogenising liver too vigorously, acid phosphatase appears mostly in the final supernatant. Explain and suggest a fix. 4 marks
Harsh homogenisation broke lysosome membranes, so the soluble enzyme leaked into the cytosol and stays in the supernatant instead of pelleting with lysosomes. Use fewer or gentler pestle strokes, keep the buffer isotonic and cold, and check intactness with a latency assay.
Beyond the syllabus
Not for the exam. Organelle proteomics combines gradient fractionation with mass spectrometry: by matching each protein's profile across fractions to known markers, thousands of proteins can be assigned to organelles in one experiment ("spatial proteomics"). Immuno-isolation pulls out one organelle with antibody-coated magnetic beads for very pure samples. Search next: "spatial proteomics LOPIT" and "organelle immunoprecipitation".
6.7 Flow cytometry
A flow cytometer pushes cells one at a time through a laser beam and measures, for each cell, how it scatters light and how brightly it glows in several colours. It reads thousands of cells per second, so instead of looking at a few cells under a microscope you get numbers for a whole population: what percentage are CD4 T cells, how many are dividing, how many are dying. A cell sorter (FACS) can then separate the cells you want.
The three systems
- Fluidics. The cell suspension is injected into a faster stream of sheath fluid. Hydrodynamic focusing squeezes the sample into a narrow core, so cells pass the laser in single file.
- Optics. One or more lasers (488 nm blue is the classic) hit each cell. Light scattered at small angles along the beam is forward scatter (FSC), which rises with cell size. Light scattered at about 90° is side scatter (SSC), which rises with internal complexity or granularity. Fluorescence from dyes or labelled antibodies is split by dichroic mirrors and filters into colour channels.
- Electronics. Photodetectors (photomultiplier tubes or photodiodes) turn each flash into a voltage pulse. The pulse height, area and width are digitised for every channel of every cell (each cell is an "event").
Reading the data: gates and plots
Data are shown as histograms (one parameter: number of cells against intensity) or dot plots (two parameters, one dot per cell). A gate is a region you draw to keep only some events: first FSC against SSC to keep intact cells and drop debris, then a pulse area against width plot to drop doublets (two cells stuck together), then the fluorescence of interest. Because dye emission spectra overlap, part of one dye's signal leaks into the next channel; compensation subtracts that leak using single-stained controls. Blood is the classic example: on FSC against SSC, lymphocytes (small, smooth), monocytes (larger) and granulocytes (high SSC from granules) form three separate clouds.
Common uses
- Immunophenotyping: fluorescent antibodies against surface CD markers count cell types; CD4 T-cell counts guide HIV care, and marker panels classify leukaemias.
- Cell cycle: a DNA dye such as propidium iodide (PI) on fixed cells gives a histogram with a G1 peak (2N DNA), a G2/M peak at twice the intensity (4N) and S phase in between.
- Apoptosis: annexin V binds phosphatidylserine, which flips to the outer leaflet early in apoptosis; PI enters only cells whose membrane has broken.
- Sorting (FACS): the stream is vibrated into droplets; a droplet holding a wanted cell is given a charge and deflected by charged plates into a collection tube.
Worked example
Question (5 marks). Cancer cells are treated with a drug and stained with annexin V–FITC and PI. Of 20,000 gated events: 14,000 are annexin⁻ PI⁻, 3,000 annexin⁺ PI⁻, 2,400 annexin⁺ PI⁺ and 600 annexin⁻ PI⁺. Give the percentage in each state and the total apoptotic fraction.
- Live (annexin⁻ PI⁻): 14,000 / 20,000 = 70%.
- Early apoptotic (annexin⁺ PI⁻: PS exposed, membrane intact): 3,000 / 20,000 = 15%.
- Late apoptotic or secondary necrotic (annexin⁺ PI⁺): 2,400 / 20,000 = 12%.
- Necrotic or damaged (annexin⁻ PI⁺): 600 / 20,000 = 3%.
- Total apoptotic = 15 + 12 = 27%. Compare with an untreated control before saying the drug caused it.
Exam traps
- FSC relates to size, SSC to granularity or internal complexity; not the other way round.
- Flow cytometry gives no image of the cell (imaging flow cytometers aside); it gives numbers per cell.
- FACS means fluorescence-activated cell sorting; analysis alone is flow cytometry.
- Annexin V binds phosphatidylserine on the outside of the cell; PI marks broken membranes, not apoptosis itself.
Check yourself
Remember What do FSC and SSC measure? 2 marks
FSC: roughly cell size. SSC: internal complexity or granularity.
Understand What is hydrodynamic focusing and why is it needed? 3 marks
The sample stream is injected into faster sheath fluid, which narrows it to a thin core so cells pass the laser one at a time; otherwise two cells would be read as one event.
Understand Why is compensation needed in multicolour experiments? 2 marks
Emission spectra overlap, so part of one dye's light is detected in another dye's channel; compensation subtracts that spillover.
Apply In a PI cell-cycle histogram the G1 peak is at intensity 200. Where is the G2/M peak, and where are S-phase cells? 2 marks
G2/M at about 400 (twice the DNA); S-phase cells lie between 200 and 400.
Analyze Why do you gate on FSC against SSC before looking at fluorescence? 3 marks
Debris, dead fragments and clumps also give fluorescence events. Gating on intact single cells by size and complexity first removes them, so percentages refer to real cells.
Beyond the syllabus
Not for the exam. Spectral flow cytometers record each cell's whole emission spectrum and unmix 30 or more colours. Mass cytometry (CyTOF) labels antibodies with metal isotopes and reads them by mass spectrometry. In CAR-T cell therapy, flow cytometry checks every manufactured batch. Search next: "spectral flow cytometry" and "mass cytometry CyTOF".
6.8 Immunostaining and protein localization
Immunostaining uses antibodies to find one protein among thousands in a fixed cell or tissue and make it visible, by a fluorescent dye (immunofluorescence) or a coloured enzyme product (immunohistochemistry). It answers the question "where in the cell is my protein?": in the nucleus, on mitochondria, at the plasma membrane. Protein localisation also uses GFP fusions in live cells and fractionation with Western blots.
Antibodies as probes
An IgG antibody is a Y-shaped protein of two heavy and two light chains. The two tips (the Fab arms) bind one small region of the target, the epitope; the stem (the Fc region) is the same for all antibodies of one species and class. A monoclonal antibody comes from one B-cell clone and binds one epitope; a polyclonal serum is a mixture binding several epitopes, which gives a stronger but less defined signal.
- Direct staining: the primary antibody itself carries the label. Fewer steps, weaker signal.
- Indirect staining: an unlabelled primary antibody (say, raised in rabbit) binds the target; a labelled secondary antibody (goat anti-rabbit IgG) binds the primary's Fc. Several secondaries bind each primary, so the signal is amplified, and one labelled secondary works with any rabbit primary.
The immunofluorescence protocol
- Fix: 4% paraformaldehyde cross-links proteins and holds them in place; cold methanol instead precipitates proteins and also permeabilises.
- Permeabilise (after aldehyde fixation): a detergent such as Triton X-100 or saponin opens membranes so antibodies (about 150 kDa) reach inside.
- Block with BSA or serum from the secondary's host species, which coats sticky sites and cuts background.
- Primary antibody, diluted (often 1:100 to 1:1000), usually 1 h at room temperature or overnight at 4 °C; wash.
- Secondary antibody with a fluorophore, in the dark; wash.
- Counterstain nuclei with DAPI, mount in antifade medium and image by fluorescence or confocal microscopy.
Controls make the result believable: a secondary-only control (no primary) shows background; an isotype control for monoclonals; and the best test of specificity, cells where the gene is knocked out or knocked down, which should lose the signal.
Immunohistochemistry and histochemical staining
In immunohistochemistry (IHC), used in pathology on tissue sections, the secondary antibody carries an enzyme, usually horseradish peroxidase (HRP). HRP with its substrate DAB (diaminobenzidine) and hydrogen peroxide gives a brown precipitate where the target is; the section is counterstained with haematoxylin (nuclei blue) and viewed in bright-field. Breast cancer biopsies are routinely stained this way for oestrogen receptor and HER2. Plain histochemical stains work without antibodies: haematoxylin and eosin (H&E) shows nuclei purple-blue and cytoplasm pink; periodic acid–Schiff (PAS) stains glycogen and mucins magenta.
Finding where a protein lives
Three methods support one another:
- Co-localisation with organelle markers: stain your protein green and a known marker red, for example TOM20 (mitochondria), calnexin (ER), GM130 (Golgi) or LAMP1 (lysosomes). Overlap shows yellow in a merged image, and a correlation value such as Pearson's coefficient (from −1 to +1) puts a number on it. Use confocal images, since widefield blur creates false overlap.
- Fluorescent protein fusions: fuse GFP to your protein's gene and watch it in living cells, including how it moves. Check that the tag does not hide a targeting signal, such as an N-terminal mitochondrial presequence.
- Fractionation and Western blot: separate nuclear, mitochondrial, membrane and cytosolic fractions (Chapter 6.6), run each on a gel and probe with your antibody plus marker antibodies.
Worked example 1: design an experiment
Question (8 marks). A new human protein X is suspected to sit in mitochondria. You have a rabbit anti-X antibody. Design an experiment to test this and say what result would support it.
- Grow cells on coverslips; fix in 4% paraformaldehyde for 15 min; permeabilise with 0.1% Triton X-100; block with 5% goat serum.
- Primary antibodies together: rabbit anti-X and mouse anti-TOM20 (mitochondrial outer membrane marker).
- Secondaries: goat anti-rabbit with a green dye; goat anti-mouse with a red dye. Counterstain DAPI.
- Controls: secondaries only; cells with X knocked down by siRNA.
- Image by confocal microscopy in separate channels to avoid bleed-through.
- Support: green and red overlap in thread-like networks (yellow in the merge), Pearson's coefficient near +1, and the signal falls after knockdown. Confirm by fractionation: X should appear in the mitochondrial fraction with TOM20 in a Western blot, not with the cytosolic marker LDH.
Worked example 2: diluting an antibody
Question (2 marks). You need 5 mL of primary antibody at 1:500. How much stock and how much blocking buffer?
- Stock volume = 5 mL ÷ 500 = 0.010 mL = 10 µL.
- Buffer = 5,000 µL − 10 µL = 4,990 µL.
Exam traps
- The secondary antibody binds the primary antibody's Fc region, not the target protein.
- Aldehyde-fixed cells need a separate permeabilisation step; methanol fixation already permeabilises.
- The secondary must be raised against the primary's host species: a rabbit primary needs an anti-rabbit secondary.
- Overlap in a widefield image is weak evidence; confocal sections plus a number (Pearson's) and a second method are expected.
- Immunofluorescence uses fluorophores; IHC usually uses HRP–DAB and a bright-field microscope.
Check yourself
Remember Name the substrate that HRP turns into a brown precipitate in IHC. 1 mark
DAB (3,3′-diaminobenzidine), with hydrogen peroxide.
Remember Give one marker protein each for mitochondria, ER and Golgi. 3 marks
TOM20 (mitochondria), calnexin (ER), GM130 (Golgi).
Understand Why does indirect staining give a brighter signal than direct staining? 2 marks
Several labelled secondary antibodies bind each primary antibody, so each target carries more fluorophores.
Understand What is the purpose of the blocking step? 2 marks
Proteins such as BSA or serum coat non-specific binding sites, so antibodies stick only to their epitope and background falls.
Apply A secondary antibody is used at 1:1000 in 20 mL. How much stock? 1 mark
20 mL ÷ 1000 = 20 µL in 19.98 mL buffer.
Apply You see bright staining in the secondary-only control. What does it mean and what will you change? 3 marks
The secondary binds non-specifically, so the real staining cannot be trusted. Block longer or with serum of the secondary's host, dilute the secondary more, wash more, or change the secondary.
Analyze A GFP fusion of protein Y shows cytosol, but antibody staining shows mitochondria. Give two explanations. 4 marks
(1) GFP on the N-terminus masked the mitochondrial targeting presequence, so the fusion stays in the cytosol; try a C-terminal tag. (2) The antibody cross-reacts with a mitochondrial protein; test it in knockout cells and by Western blot of fractions.
Beyond the syllabus
Not for the exam. The Human Protein Atlas has mapped the subcellular location of most human proteins by immunofluorescence and makes the images free online. Proximity labelling (BioID, APEX) tags neighbouring proteins with biotin in living cells to map compartments by mass spectrometry. Multiplexed imaging stains 40 or more proteins on one tissue section, now used in cancer research. Search next: "Human Protein Atlas subcellular" and "proximity labelling APEX".
Unit summary
| Term | Meaning or formula | Chapter |
|---|---|---|
| Nernst equation | E = 61.5 mV × log₁₀(C_out / C_in) for a +1 ion at 37 °C | 6.1 |
| Action potential | All-or-none spike: Na⁺ in (to about +30 mV), then K⁺ out; threshold about −55 mV | 6.1 |
| Saltatory conduction | Spike jumps between nodes of Ranvier in myelinated axons | 6.1 |
| Sarcomere bands | A band = thick filament (constant); I band = sarcomere − A band; H zone = sarcomere − 2 × thin filament | 6.2 |
| Cross-bridge cycle | ATP binding detaches myosin; Pi release drives the power stroke | 6.2 |
| Phototransduction | Light → rhodopsin → transducin → PDE6 → cGMP falls → channels close → hyperpolarisation | 6.3 |
| β-cell coupling | Glucose → ATP/ADP up → K_ATP closes → depolarisation → Ca²⁺ in → insulin exocytosis | 6.3 |
| Resolution (Rayleigh) | d = 0.61 λ / NA; NA = n sin θ | 6.4 |
| Haemocytometer | cells/mL = mean count per large square × 10⁴ × dilution factor | 6.4 |
| Electron wavelength | λ ≈ 1.226 / √V nm (non-relativistic) | 6.5 |
| RCF | RCF = 1.118 × 10⁻⁵ × r(cm) × rpm² | 6.6 |
| Enrichment and yield | Enrichment = SA fraction ÷ SA homogenate; yield = units fraction ÷ units homogenate × 100% | 6.6 |
| FSC and SSC | Forward scatter ≈ size; side scatter ≈ granularity | 6.7 |
| Indirect immunostaining | Unlabelled primary + labelled secondary against the primary's Fc | 6.8 |
- A specialised cell expresses its own set of proteins and builds its shape around one job; the genome is the same in every cell.
- Neurons signal by an all-or-none action potential (Na⁺ in, K⁺ out) and pass it on at synapses by Ca²⁺-triggered exocytosis; myelin makes conduction fast and cheap.
- All three muscle types use actin–myosin sliding; skeletal and cardiac switch it on through troponin, smooth muscle through calmodulin and myosin light-chain kinase.
- Light hyperpolarises photoreceptors through a G-protein cascade that lowers cGMP; β cells turn rising glucose into ATP, close K_ATP channels and release insulin.
- Resolution depends on wavelength and numerical aperture (d = 0.61 λ / NA), not on magnification; the light limit is about 0.2 µm.
- Fluorescence relies on the Stokes shift and a filter cube; confocal pinholes remove out-of-focus light; electron microscopes reach nanometre detail but need dead, prepared samples.
- Fractionation separates organelles by size (differential, rate-zonal) or density (isopycnic), checked by marker enzymes, enrichment and yield.
- Flow cytometry measures scatter and fluorescence of single cells in thousands per second; immunostaining and co-localisation place a protein in its compartment.
Exam question bank
Remember and understand
Remember Draw a labelled diagram of a myelinated neuron and state the function of each part. 8 marks
Outline: dendrites (receive), soma with nucleus and Nissl bodies (synthesis), axon hillock (spike starts), axon (conducts), myelin by Schwann cells or oligodendrocytes (insulation), nodes of Ranvier (spike regenerated), terminals and synapse (transmitter release). Neat diagram with 7 or more labels.
Understand Explain the ionic basis of the resting potential and of the action potential. 12 marks
Outline: Na⁺/K⁺ pump (3 out, 2 in) sets gradients; K⁺ leak gives rest near EK; Nernst equation with values; threshold, Na⁺ channel opening, peak, inactivation, K⁺ efflux, undershoot; refractory period and one-way travel; all-or-none; saltatory conduction. A labelled voltage–time graph.
Understand Compare skeletal, cardiac and smooth muscle cells, and describe the sliding filament mechanism. 12 marks
Outline: comparison table (shape, nuclei, striations, control, junctions, Ca²⁺ switch); sarcomere bands and what changes; excitation–contraction coupling (T-tubule, DHP and ryanodine receptors, Ca²⁺, troponin–tropomyosin); cross-bridge cycle with the role of ATP; relaxation by SERCA.
Understand Describe the principle, parts and sample preparation of the transmission and scanning electron microscopes. 12 marks
Outline: electron source, vacuum, electromagnetic lenses; transmission vs surface scanning; TEM preparation (glutaraldehyde, OsO₄, dehydration, resin, ultramicrotomy, uranyl acetate and lead citrate); SEM preparation (critical-point drying, sputter coating); resolution compared with light; images each is best for.
Apply
Apply Derive the resolution limit of the light microscope and calculate it for λ = 500 nm with dry (NA 0.95) and oil (NA 1.40) objectives. 8 marks
Outline: diffraction blur and Rayleigh criterion; d = 0.61 λ / NA, NA = n sin θ; dry: 0.61 × 500 / 0.95 = 321 nm; oil: 0.61 × 500 / 1.40 = 218 nm; why oil helps; empty magnification.
Apply Outline a protocol to isolate mitochondria from rat liver and show how you would prove the fraction is pure. Include RCF calculations for a rotor of radius 7 cm. 16 marks
Outline: cold isotonic sucrose buffer, Potter–Elvehjem homogeniser; 1,000 g pellet discarded; 10,000–20,000 g pellet kept; isopycnic gradient to remove peroxisomes and lysosomes; markers (SDH up, catalase, acid phosphatase, glucose-6-phosphatase down); specific activity, enrichment, yield; rpm for 1,000 g ≈ 3,600 and for 15,000 g ≈ 13,800 (rpm = √(RCF / (1.118 × 10⁻⁵ × 7))).
Apply Describe the principle and instrumentation of flow cytometry and use it to measure apoptosis in drug-treated cells. 12 marks
Outline: fluidics (hydrodynamic focusing), optics (laser, FSC, SSC, fluorescence filters), electronics (PMTs, pulses); gating and compensation; annexin V and PI principle; four-quadrant reading with a sample calculation; FACS sorting; controls.
Apply Describe indirect immunofluorescence step by step to show that a protein is in the Golgi, with the controls you would include. 10 marks
Outline: fixation and permeabilisation choices; blocking; primary anti-protein plus anti-GM130 from different species; matching labelled secondaries; DAPI; confocal imaging; merge and Pearson's coefficient; secondary-only and knockdown controls; confirm by fractionation and Western blot.
Analyze and evaluate
Analyze Compare widefield fluorescence, confocal and electron microscopy for studying the mitochondrial network of a living cell and its cristae. Which would you choose for each question? 10 marks
Outline: widefield is fast and gentle but blurred in thick cells; confocal gives optical sections and 3D of the live network (with a mitochondrial dye or GFP), at the cost of bleaching; cristae (tens of nanometres) need TEM of fixed sections. Choose confocal for the network, TEM for cristae; mention resolution values.
Analyze Neurons, muscle cells and β cells all use Ca²⁺ to trigger their output. Compare where the Ca²⁺ comes from and what it triggers in each. 12 marks
Outline (spans 6.1–6.3): nerve terminal, voltage-gated Ca²⁺ channels from outside, vesicle exocytosis; skeletal muscle, Ca²⁺ from the SR via ryanodine receptors, binds troponin; smooth muscle, calmodulin and MLCK; β cell, voltage-gated channels after K_ATP closure, insulin granule exocytosis. Common theme: depolarisation → Ca²⁺ rise → output; the end-point differs.
Analyze Two methods place a protein in different compartments: fractionation says ER, immunofluorescence says cytosol. Evaluate the possible causes and design experiments to resolve the conflict. 12 marks
Outline (spans 6.6 and 6.8): fractionation artefacts (protein sticking to microsomes, cross-contamination; check markers and salt washes); staining artefacts (antibody cross-reaction, fixation extracting membranes, widefield blur); tests: knockout control, a second antibody, GFP fusion with both N- and C-terminal tags, confocal co-localisation with calnexin, protease-protection assay of microsomes.
Analyze A classmate counts 80 cells per large haemocytometer square from a 1:20 dilution and reports 1.6 × 10⁵ cells/mL. Find the mistake and give the correct value. 8 marks
Outline: correct value = 80 × 10⁴ × 20 = 1.6 × 10⁷ cells/mL. The classmate multiplied by 10² instead of 10⁴, likely from forgetting the 0.1 mm depth and the mm³-to-mL conversion. Also discuss counting rules (cells on two borders only), viability by trypan blue, and why 4 or more squares are averaged.
Glossary
- Action potential
- A brief, all-or-none reversal of membrane voltage that travels along an axon or muscle fibre.
- Annexin V
- A protein that binds phosphatidylserine exposed on the outer surface of apoptotic cells.
- Axon hillock
- Where the axon leaves the cell body; the action potential starts there.
- cGMP
- Cyclic GMP; holds photoreceptor cation channels open in the dark.
- Compensation
- Correction for one dye's light spilling into another dye's detector in flow cytometry.
- Confocal microscope
- A point-scanning fluorescence microscope whose detector pinhole rejects out-of-focus light.
- Cross-bridge
- A myosin head bound to actin during contraction.
- Dichroic mirror
- A mirror that reflects short wavelengths and transmits longer ones.
- Differential centrifugation
- Spinning at rising speeds to pellet particles in order of size.
- Epitope
- The small part of an antigen that an antibody binds.
- FACS
- Fluorescence-activated cell sorting: a flow cytometer that also separates cells.
- Haemocytometer
- A counting chamber of known depth and grid area used to count cells.
- Immunohistochemistry
- Antibody staining of tissue sections, usually with an enzyme such as HRP that makes a coloured product.
- Isopycnic centrifugation
- Separation by density: particles stop where the gradient density equals their own.
- Islets of Langerhans
- Endocrine clusters in the pancreas containing α, β, δ and PP cells.
- K_ATP channel
- A K⁺ channel closed by ATP; it couples glucose metabolism to insulin release.
- Marker enzyme
- An enzyme found in one organelle only, used to trace it in fractions.
- Microsomes
- Small vesicles formed from ER and other membranes during homogenisation.
- Myelin
- Wrapped membrane layers around an axon that insulate it.
- Numerical aperture (NA)
- n sin θ; the light-gathering power of an objective, which sets its resolution.
- Photobleaching
- Loss of fluorescence as light destroys the fluorophore.
- Resolution
- The smallest distance at which two points can be seen as separate.
- Rhodopsin
- The rod visual pigment: opsin plus 11-cis-retinal.
- Sarcomere
- The contractile unit of striated muscle, from one Z line to the next.
- Secondary antibody
- A labelled antibody that binds the Fc region of a primary antibody.
- Side scatter (SSC)
- Light scattered at about 90°, reflecting a cell's internal complexity.
- Specific activity
- Enzyme units per mg of protein; a measure of purity.
- Stokes shift
- The difference between excitation and longer emission wavelength of a fluorophore.
- Svedberg (S)
- Unit of sedimentation coefficient, 10⁻¹³ s.
Sources and further reading
- Alberts B. et al., Molecular Biology of the Cell, 7th edition (2022), W. W. Norton: chapters on visualising cells, analysing cells and molecules, and the cytoskeleton (from memory; check).
- Lodish H. et al., Molecular Cell Biology, W. H. Freeman: chapters on culturing, visualising and fractionating cells, and on nerve cells (from memory; check).
- Karp G., Cell and Molecular Biology: Concepts and Experiments, Wiley: chapter on techniques in cell and molecular biology (from memory; check).
- Cooper G. M., The Cell: A Molecular Approach, Sinauer/Oxford University Press: chapter on tools of cell biology (from memory; check).
- Hall J. E., Guyton and Hall Textbook of Medical Physiology, Elsevier: chapters on membrane potentials, skeletal muscle contraction, the retina and insulin (from memory; check).
- Wikipedia, "Cell fractionation": en.wikipedia.org/wiki/Cell_fractionation (overview of homogenisation and isotonic, cold buffers).
- Abcam, "Cell fractionation: a complete overview": abcam.com knowledge center (differential and density-gradient centrifugation, purity checks by Western blot).
Syllabus: the University free n easy universal syllabus, built from top universities’ syllabi.