These are the notes for Lesson 1 · Physical and chemical control of the University free n easy video lessons on Microbiology Unit 5, Control of Microorganisms. They are chapters 5.1 to 5.2 of the unit book, unchanged, so a page here is the same page in the full book.
5.1 Physical control: heat, filtration and radiation
Physical control means killing or removing microbes with energy or a barrier instead of a chemical: steam in an autoclave, a hot air oven, a membrane filter, a UV lamp or a gamma source. Every microbiology lab, hospital and food factory depends on it, because no culture, injection or canned food is safe unless the unwanted microbes are gone first. The skill this chapter builds is choosing the right method for the material and knowing how long it must run.
Words first: how much is "clean"?
Sterilization destroys or removes all living forms, including bacterial endospores. It is absolute: an object is sterile or it is not. Disinfection kills most disease-causing microbes on an object or surface, but not all spores. Antisepsis is disinfection of living tissue such as skin. Sanitization lowers microbial numbers to a level public-health rules accept, as in a restaurant dishwasher.
A suffix tells you what an agent does. -cidal agents kill (bactericidal, sporicidal, virucidal). -static agents only stop growth (bacteriostatic); remove the agent and growth starts again. Refrigeration is bacteriostatic; autoclaving is cidal.
How microbes die: D-value and z-value
When a population is heated at a constant temperature, it does not die all at once. In each minute, the same fraction of the survivors dies. So the number of survivors falls by a constant factor per unit time, and a plot of log₁₀(survivors) against time is a straight line. This is first-order (logarithmic) death:
N = N₀ × 10^(−t / D) or log₁₀N = log₁₀N₀ − t / D
Here N₀ is the starting number of cells or spores, N is the number alive after time t, and D (decimal reduction time) is the time at a stated temperature that kills 90% of the population, that is, one log cycle. D is written with its temperature, for example D₁₂₁ = 1.5 min.
The z-value is the rise in temperature that makes D ten times smaller. For many bacterial spores z is close to 10 °C, so the D at a lower temperature T is D_T = D_ref × 10^((T_ref − T)/z). The F-value is the total lethality of a process, expressed as minutes at a reference temperature; F₀ means minutes at 121.1 °C with z = 10 °C, and Chapter 5.5 uses it for canning. Older books use thermal death point and thermal death time; both depend on the starting number of cells, which is why D replaced them.
Killing never reaches exactly zero, so a process aims at a sterility assurance level (SAL); medical devices are usually sterilized to 10⁻⁶, a one-in-a-million chance that an item carries a survivor. A dirtier load (bigger N₀) needs a longer run.
Heat: moist and dry
Moist heat kills by denaturing and coagulating proteins, and water makes proteins unfold at lower temperatures. Steam also gives up its latent heat when it condenses on a cold object, so it heats the load fast. That is why steam at 121 °C works in minutes while dry air at the same temperature takes hours.
- Autoclave: saturated steam at about 15 psi (about 103 kPa) above atmospheric pressure, which raises the boiling point to 121 °C. Textbooks quote 15 minutes for small unwrapped loads; the US CDC guideline gives 30 minutes at 121 °C for wrapped instruments in a gravity-displacement autoclave, and 4 minutes at 132 °C in a prevacuum autoclave. Air must be driven out first, because an air pocket stays cooler than steam. Used for media, instruments and discarded cultures.
- Boiling at 100 °C for 10 to 30 minutes kills vegetative cells and most viruses, but not all endospores. It disinfects; it does not sterilize.
- Tyndallization (intermittent sterilization): steaming at 100 °C for about 30 minutes on three successive days. Spores that survive day one germinate overnight and the young vegetative cells die the next day. Used for media that 121 °C would spoil.
- Pasteurization: mild heat that kills pathogens and lowers spoilage organisms in milk and juice without cooking them. The batch (LTLT) method is 63 °C for 30 minutes; the flash (HTST) method is 72 °C for 15 seconds.
Dry heat kills mainly by oxidation and needs higher temperatures for longer. The hot air oven runs at 160 °C for 2 hours or 170 °C for 1 hour, for glassware, metal instruments, oils and powders that steam cannot reach or would damage. Incineration burns waste to ash, and flaming an inoculation loop red-hot sterilizes it in seconds.
A cycle is checked with indicators. Chemical indicator tape changes colour when heated, which proves the temperature was reached but not that spores died. A biological indicator is a strip of resistant spores, Geobacillus stearothermophilus for steam, incubated after the run; no growth means the cycle worked.
Filtration and radiation
Filtration removes microbes instead of killing them, so it suits heat-sensitive liquids such as antibiotic solutions, vitamins, serum and enzyme solutions. A membrane filter (cellulose ester or polycarbonate) with 0.22 µm pores holds back bacteria; 0.45 µm membranes are used to collect bacteria from water for counting. Viruses and some mycoplasmas pass through 0.22 µm pores, so a filtered liquid is not strictly sterile for them. Air is filtered by HEPA filters, which trap at least 99.97% of 0.3 µm particles; they supply laminar airflow hoods, biosafety cabinets and operating theatres.
Ionizing radiation (gamma rays from cobalt-60, electron beams, X-rays) knocks electrons off water molecules and makes hydroxyl radicals that break DNA. It penetrates packaging, so plastic syringes, catheters, gloves, sutures and Petri plates are sterilized after sealing, without heat; this is called cold sterilization. Ultraviolet light near 260 nm, where DNA absorbs most strongly, joins neighbouring pyrimidines into dimers (mostly thymine dimers) that block replication; germicidal lamps emit at 254 nm. UV does not penetrate glass, paper or thick liquid, so it only treats air, surfaces and thin films of water.
Cold, drying and high salt or sugar mostly stop growth rather than kill; they return as food preservation in Chapter 5.5.
Worked example
Question (8 marks). One litre of medium carries 10⁵ spores per mL. For these spores D₁₂₁ = 1.5 min and z = 10 °C. (a) How long at 121 °C reduces the load to one surviving spore? (b) How long gives a sterility assurance level of 10⁻⁶? (c) If the autoclave only reaches 115 °C, how long is needed for (b)?
- Starting load: N₀ = 10⁵ spores/mL × 1000 mL = 10⁸ spores, so log₁₀N₀ = 8.
- (a) Reaching N = 1 (log 0) needs 8 log reductions. Time = 8 × D = 8 × 1.5 = 12 min.
- (b) SAL 10⁻⁶ means log₁₀N = −6, so 8 − (−6) = 14 log reductions. Time = 14 × 1.5 = 21 min.
- (c) D at 115 °C: D₁₁₅ = 1.5 × 10^((121 − 115)/10) = 1.5 × 10^0.6 = 1.5 × 3.98 = 5.97 min.
- Time = 14 × 5.97 = 83.6 min, about four times longer for a 6 °C drop.
These times start only when the centre of the flask reaches the set temperature, so large loads need longer cycles.
Exam traps
- Pressure does not kill; it only raises the boiling point so steam can reach 121 °C. An autoclave full of trapped air at 15 psi is cooler and fails.
- Boiling and pasteurization are not sterilization. Spores survive both.
- D is the time for a 90% kill, not 100%. A 99.9% kill is 3D.
- Filtration removes, it does not kill; and 0.22 µm filters let viruses through.
- UV has poor penetration; gamma rays penetrate. Do not swap them in "sterilization of disposable syringes" answers.
Check yourself
Remember State the standard conditions for a hot air oven and for an autoclave. 2 marks
Hot air oven: 160 °C for 2 h (or 170 °C for 1 h). Autoclave: saturated steam at 121 °C, about 15 psi above atmospheric, 15 min for small loads (longer for wrapped or large loads).
Remember Which organism's spores are used as the biological indicator for steam sterilization? 1 mark
Geobacillus stearothermophilus.
Understand Why does moist heat sterilize faster than dry heat at the same temperature? 3 marks
Water helps proteins unfold and coagulate at lower temperatures, and condensing steam releases latent heat that warms the load quickly. Dry heat kills by slow oxidation and air transfers heat poorly.
Understand Explain the principle of tyndallization. 3 marks
Steaming at 100 °C kills vegetative cells but not spores. During overnight incubation surviving spores germinate into heat-sensitive vegetative cells, which the next day's steaming kills. Three cycles leave the medium sterile without exposing it to 121 °C.
Apply A culture has 10⁷ cells; D₇₂ = 0.5 s. How many survive 15 s at 72 °C? 3 marks
Log reductions = 15/0.5 = 30. log₁₀N = 7 − 30 = −23, so N = 10⁻²³: effectively none survive.
Apply Choose a method to sterilize (i) a vitamin solution, (ii) plastic Petri plates in sealed packs, (iii) glass pipettes. 3 marks
(i) Membrane filtration through 0.22 µm. (ii) Gamma or electron-beam irradiation. (iii) Hot air oven, 160 °C for 2 h.
Analyze An autoclave run's indicator tape changed colour but the spore strip grew. Give two likely causes. 4 marks
The tape only shows the surface got hot. Likely causes: air was not removed, so the load centre stayed below 121 °C; the cycle was too short for a large or wrapped load; or the load was packed too tightly for steam to reach it.
Beyond the syllabus
Industry validates sterilization against international standards: ISO 17665 for moist heat and ISO 11137 for radiation sterilization of health care products, both built on the D-value and SAL ideas above. Heat-sensitive devices are often treated with hydrogen peroxide gas plasma, and UV-C LEDs are replacing mercury lamps for water disinfection. Search "sterility assurance level", "overkill method" and "bioburden method" to see how a cycle is designed. This is not for the exam.
5.2 Chemical control: disinfectants and antiseptics
Chemical control uses substances that kill or inhibit microbes on surfaces, instruments, water and skin, where heat cannot be used. The Dettol in a hospital mop bucket, bleaching powder in a village well, 70% alcohol on a vaccination swab and glutaraldehyde for an endoscope are all chemical agents chosen for one job. Each class attacks a different part of the cell, and each fails in a predictable way, which is what examiners ask about.
Terms and how to choose an agent
A disinfectant is used on non-living objects; it may be too harsh for tissue. An antiseptic is mild enough for skin and mucous membranes. A sanitizer brings counts down to a safe public-health level, as on food-contact surfaces. A sterilant (chemosterilant) kills spores too, given enough time. The general word germicide covers all of them.
Hospitals pick the level of treatment from what the item touches (the Spaulding classification). Critical items enter sterile tissue or blood, such as surgical instruments and needles, and must be sterile. Semicritical items touch mucous membranes, such as endoscopes, and need high-level disinfection. Noncritical items touch only intact skin, such as BP cuffs and bed rails, and need low-level disinfection.
Microbes are not equally easy to kill. Figure 5.2.1 ranks them. An agent that kills a group also kills every group below it, so an alcohol that kills mycobacteria also kills vegetative bacteria and enveloped viruses.
What affects a disinfectant
- Concentration and contact time. Killing follows the same first-order pattern as heat (Chick's law). Watson added the effect of concentration: Cⁿ × t = K, where C is concentration, t the time for a given kill, K a constant and n the concentration exponent. A large n means dilution weakens the agent sharply; for phenol n is about 6.
- Organic matter. Blood, pus, faeces and food residues react with chlorine, iodine and quaternary ammonium compounds and use them up. Clean first, then disinfect.
- Temperature and pH. Warmer usually works faster. Chlorine is far stronger at slightly acidic pH, because the killing form, hypochlorous acid (HOCl), turns into weaker hypochlorite ion (OCl⁻) as pH rises.
- Number and state of microbes. More cells take longer; biofilms (Unit 6, Biofilms) and dried films are protected.
The main classes
| Class | Examples | How it acts | Typical use and limits |
|---|---|---|---|
| Phenolics | phenol, cresols, chloroxylenol (Dettol) | damage membranes, denature proteins | floors, discarded cultures; work in organic matter; irritate skin. Lister used phenol (carbolic acid) in surgery in the 1860s. |
| Alcohols | ethanol, isopropanol, 60 to 90% in water | denature proteins, dissolve membrane lipids | skin before injection, hand rubs, thermometers; need water to work, evaporate fast, do not kill spores. |
| Halogens | sodium hypochlorite (bleach), bleaching powder, chloramines; tincture of iodine, povidone-iodine | oxidize proteins and other cell parts | drinking water, blood spills, surgical skin preparation; chlorine is used up by organic matter. |
| Biguanides | chlorhexidine | disrupt membranes | surgical hand scrub, mouthwash; Savlon combines it with cetrimide. |
| Quaternary ammonium compounds | benzalkonium chloride, cetrimide | cationic detergents that disrupt membranes | floors, food-contact surfaces; stronger against Gram-positives; inactivated by soap and organic matter; some Pseudomonas grow in weak solutions. |
| Heavy metals | silver nitrate, silver sulfadiazine, copper sulfate | bind thiol (–SH) groups of proteins | burn dressings, algicide in tanks; tiny amounts act (oligodynamic action). |
| Aldehydes | 2% glutaraldehyde, formaldehyde | alkylate amino and other groups of proteins and nucleic acids | endoscopes, fumigation of rooms; slow, toxic, irritant. |
| Gas | ethylene oxide (EtO) | alkylates proteins and DNA | sterilizes heat-sensitive plastics and devices; penetrates packs; toxic, explosive, needs aeration. |
| Peroxygens | hydrogen peroxide, peracetic acid, ozone | oxidize via reactive oxygen | wounds (3% H₂O₂), sterilant for devices, water; catalase-producing bacteria resist weak H₂O₂. |
Soap is not in the table because it mainly removes microbes: it lifts oil and dirt so that rinsing carries cells away, which is called degerming.
Testing how good a disinfectant is
The phenol coefficient compares an agent with phenol against a standard organism. In the Rideal–Walker test, the test organism is Salmonella Typhi; dilutions of the agent and of phenol are inoculated, sampled at fixed minutes and cultured. The phenol coefficient is the highest dilution of the agent that kills in a stated time divided by the same dilution for phenol. The Chick–Martin test adds organic matter (yeast) to mimic real use. Because a single number hides the effect of dirt and surfaces, modern labs prefer the use-dilution test, where bacteria dried on steel carriers are dipped in the recommended dilution, and in-use tests, where samples from disinfectant buckets in the ward are cultured to see if anything survives.
Worked example
Question (6 marks). In a phenol coefficient test against S. Typhi at 20 °C, phenol at 1:90 killed the organism in 10 minutes but not in 5 minutes. A new disinfectant X did the same at 1:400. (a) Find the phenol coefficient of X. (b) For phenol, n = 6. If a 1% phenol solution kills in 10 minutes, how long will a 0.5% solution take?
- (a) Phenol coefficient = dilution of X ÷ dilution of phenol for the same result = 400 ÷ 90 = 4.4. X is about four times as effective as phenol in this test.
- (b) Watson: C₁ⁿ t₁ = C₂ⁿ t₂, so t₂ = t₁ × (C₁/C₂)ⁿ.
- C₁/C₂ = 1/0.5 = 2, and 2⁶ = 64.
- t₂ = 10 min × 64 = 640 min, more than ten hours.
Halving phenol's strength makes it 64 times slower. This is why a ward that "saves" disinfectant by over-diluting it ends up with buckets in which bacteria survive.
Exam traps
- Disinfectant is for objects, antiseptic is for living tissue. The same chemical can be both at different strengths.
- Absolute (100%) alcohol is weaker than 70%; water is needed to denature proteins.
- A phenol coefficient above 1 means stronger than phenol, but it says nothing about performance in blood or on a dirty floor.
- Glutaraldehyde and ethylene oxide are sterilants; alcohol and quaternary ammonium compounds are not, because they do not kill spores.
- Do not write "chlorine is better at high pH". HOCl, the active form, dominates at slightly acidic pH.
Check yourself
Remember Name one disinfectant from each of: halogens, aldehydes, quaternary ammonium compounds. 3 marks
Halogens: sodium hypochlorite or povidone-iodine. Aldehydes: glutaraldehyde or formaldehyde. Quaternary ammonium: benzalkonium chloride or cetrimide.
Remember Which test organism is used in the Rideal–Walker test? 1 mark
Salmonella Typhi.
Understand Why must a blood spill be cleaned before it is disinfected with bleach? 2 marks
Organic matter reacts with chlorine and uses it up, so little active HOCl is left to kill microbes; the protein also shields cells. Removing it first lets the bleach act.
Understand Explain the Spaulding classification with one example of each class. 4 marks
Critical items enter sterile tissue (scalpel): sterilize. Semicritical items touch mucous membranes (endoscope): high-level disinfection. Noncritical items touch intact skin (BP cuff): low-level disinfection.
Apply An agent has n = 1. A 2% solution kills in 20 min. How long will 1% take? 2 marks
t₂ = 20 × (2/1)¹ = 40 min. With n = 1, halving strength only doubles the time.
Apply Choose an agent for: (i) a heat-sensitive plastic catheter in its pack, (ii) skin before a blood draw, (iii) a village well. 3 marks
(i) Ethylene oxide gas (or gamma radiation). (ii) 70% alcohol. (iii) Bleaching powder (chlorination).
Analyze A hospital finds Pseudomonas growing in its benzalkonium chloride bottles. Explain how and suggest a fix. 4 marks
Quaternary ammonium compounds are weaker against Gram-negatives, whose outer membrane slows entry; over-dilution, topping up old bottles and organic contamination let resistant Pseudomonas survive and grow. Fix: fresh solutions at the right strength, no topping up, clean containers, and in-use testing.
Beyond the syllabus
Regulators now test disinfectants with European EN standards and US EPA methods instead of the phenol coefficient, and they demand claims per organism and contact time. Triclosan was withdrawn from many consumer soaps after concerns about safety and resistance, and quaternary ammonium compounds are watched for the same reason. Hydrogen peroxide vapour is used to decontaminate whole hospital rooms and pharmaceutical cleanrooms. Search "EN 1276 suspension test" and "hydrogen peroxide vapour decontamination" to read further. This is not for the exam.
Key terms of this lesson
| Term | Meaning or formula | Chapter |
|---|---|---|
| Sterilization | removal or killing of all life, including endospores | 5.1 |
| Survivor equation | N = N₀ × 10^(−t/D) | 5.1 |
| D-value | time at a stated temperature for a 90% (one log) kill | 5.1 |
| z-value | temperature rise that cuts D tenfold; D_T = D_ref × 10^((T_ref − T)/z) | 5.1 |
| Autoclave | saturated steam, 121 °C, about 15 psi above atmospheric; 15 min small loads, longer for wrapped loads | 5.1 |
| Hot air oven | 160 °C for 2 h or 170 °C for 1 h | 5.1 |
| Watson's law | Cⁿ × t = K; n is the concentration exponent (about 6 for phenol) | 5.2 |
| Phenol coefficient | dilution of agent ÷ dilution of phenol giving the same kill | 5.2 |
Glossary (terms used in this lesson)
- Antibiotic
- A microbial product, or its derivative, that inhibits or kills other microbes at low concentration.
- Antiseptic
- A chemical mild enough to reduce microbes on living tissue.
- Autoclave
- Pressure vessel that sterilizes with saturated steam, usually at 121 °C.
- Biological indicator
- Resistant spores used to prove a sterilization cycle worked.
- D-value
- Time at a given temperature to kill 90% of a population.
- Disinfectant
- A chemical that kills most pathogens on non-living objects.
- MIC
- Minimum inhibitory concentration: lowest drug level that stops visible growth.
- Pasteurization
- Mild heat (63 °C for 30 min or 72 °C for 15 s) that kills pathogens in milk without sterilizing it.
- Phenol coefficient
- Effectiveness of a disinfectant compared with phenol in a standard test.
- Sterility assurance level
- Probability that an item still carries a live microbe after sterilization, often 10⁻⁶.
- Sterilization
- Destruction or removal of all life, including endospores.
- Tyndallization
- Steaming at 100 °C on three successive days to kill spores after they germinate.
- z-value
- Temperature change that alters the D-value tenfold.
The full unit book
Every chapter of Unit 5, the unit summary, the exam question bank with model answers and the full glossary: Microbiology · Unit 5 · Control of Microorganisms (one file, works offline).
Sources and further reading
Textbooks
- Willey, Sandman and Wood, Prescott's Microbiology, McGraw-Hill: chapters on control of microorganisms, antimicrobial chemotherapy and food microbiology (from memory; check).
- Pelczar, Chan and Krieg, Microbiology, McGraw-Hill (from memory; check).
- Tortora, Funke and Case, Microbiology: An Introduction, Pearson (from memory; check).
- Ananthanarayan and Paniker's Textbook of Microbiology, Universities Press: sterilization, disinfection and antibiotic chapters (from memory; check).
- Jay, Loessner and Golden, Modern Food Microbiology, Springer: intrinsic and extrinsic factors and the water activity limits in Figure 5.5.1 (from memory; check).
- Frazier and Westhoff, Food Microbiology, McGraw-Hill: spoilage by food group (from memory; check).
Open web resources
- US CDC, Guideline for Disinfection and Sterilization in Healthcare Facilities (2008), Table 7: minimum cycle times for steam sterilization, cdc.gov. Source of the 30 min (121 °C, wrapped, gravity) and 4 min (132 °C, prevacuum) figures.
- Antimicrobial Resistance Collaborators, "Global burden of bacterial antimicrobial resistance in 2019: a systematic analysis", The Lancet 2022;399:629–655, open text at PubMed Central. Source of the 1.27 million and 4.95 million figures.
Syllabus: the University free n easy universal syllabus, built from top universities’ syllabi.